|
Atomistry » Chlorine » PDB 2a7d-2aj4 » 2a7h | |||||||||||||||||
Atomistry » Chlorine » PDB 2a7d-2aj4 » 2a7h » |
Chlorine in PDB 2a7h: On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection WavelengthEnzymatic activity of On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength
All present enzymatic activity of On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength:
3.4.21.4; Protein crystallography data
The structure of On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength, PDB code: 2a7h
was solved by
C.Mueller-Dieckmann,
S.Panjikar,
P.A.Tucker,
M.S.Weiss,
with X-Ray Crystallography technique. A brief refinement statistics is given in the table below:
Other elements in 2a7h:
The structure of On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength also contains other interesting chemical elements:
Chlorine Binding Sites:
The binding sites of Chlorine atom in the On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength
(pdb code 2a7h). This binding sites where shown within
5.0 Angstroms radius around Chlorine atom.
In total 2 binding sites of Chlorine where determined in the On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength, PDB code: 2a7h: Jump to Chlorine binding site number: 1; 2; Chlorine binding site 1 out of 2 in 2a7hGo back to![]() ![]()
Chlorine binding site 1 out
of 2 in the On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength
![]() Mono view ![]() Stereo pair view
Chlorine binding site 2 out of 2 in 2a7hGo back to![]() ![]()
Chlorine binding site 2 out
of 2 in the On the Routine Use of Soft X-Rays in Macromolecular Crystallography, Part III- the Optimal Data Collection Wavelength
![]() Mono view ![]() Stereo pair view
Reference:
C.Mueller-Dieckmann,
S.Panjikar,
P.A.Tucker,
M.S.Weiss.
On the Routine Use of Soft X-Rays in Macromolecular Crystallography. Part III. the Optimal Data-Collection Wavelength. Acta Crystallogr.,Sect.D V. 61 1263 2005.
Page generated: Sat Jul 20 05:07:06 2024
ISSN: ISSN 0907-4449 PubMed: 16131760 DOI: 10.1107/S0907444905021475 |
Last articlesZn in 9J0NZn in 9J0O Zn in 9J0P Zn in 9FJX Zn in 9EKB Zn in 9C0F Zn in 9CAH Zn in 9CH0 Zn in 9CH3 Zn in 9CH1 |
© Copyright 2008-2020 by atomistry.com | ||
Home | Site Map | Copyright | Contact us | Privacy |